Following conversion to rod pumping, a Delaware Basin well began underperforming, resulting in seven workovers for tubing holes and parted rods. Molded rod guides had not resolved the failure mode, and the operator considered abandoning the well.
In December 2019, the operator installed 58 joints of Ultratube™-lined 3½-inch L-80 tubing in the sections experiencing high side loads and removed the rod guides.
Seating Nipple Depth: 9,500 ft / approximately 2,895 m
Previous Runtime Average: 101 days
Average Workover Cost: approx $75,000
Total Liner Investment: approx $45,000
In July 2020, the well was pulled after 216 days because solids had stuck the pump. After installing four new Ultratube™-lined joints, the next documented pull occurred in May 2024 for a pump change (1,400 days) at nearly 14x the historical average. The lined design also reduced modelled power losses along the rod string by over 36%, indicating less power was consumed overcoming resistance within the well.
In both the 2020 pull and the 2024 pump change, no holes-in-tubing were reported.
The total liner investment was less than the average cost of a single workover, while targeted lining helped keep a well threatened with abandonment in active production. Design modelling showed lower equipment loading and net pumping capacity increasing from 186 to 200 barrels per day at an assumed 80% efficiency.
The recovered lined tubing was inspected rather than scrapped. A large majority remained fit for further service and was returned to the operator’s inventory for redeployment in another well.
The well has not been pulled since the May 2024 pump change and remains in production, 2,510 days after the liner went in.
| Parameter | Original design | Lined tubing design |
|---|---|---|
| Rod guides | Molded, 6 per rod | None |
| Power required | 43.54 hp | 40.21 hp |
| Polished rod power | 31.56 hp | 27.43 hp |
| Power lost along rod string | 14.79 hp | 9.39 hp |
| Maximum rod load | 31,584 lb | 30,385 lb |
| Rod loading, percent of Superod guideline | 80% | 74% |
| Percent of reducer rating | 99.4% | 94.5% |
| Net pump capacity at 80% efficiency | 186 BPD | 200 BPD |
We use cookies to improve your experience on our site. By using our site, you consent to cookies.
Manage your cookie preferences below:
Essential cookies enable basic functions and are necessary for the proper function of the website.
These cookies are needed for adding comments on this website.
Google Tag Manager simplifies the management of marketing tags on your website without code changes.
Service URL: business.safety.google (opens in a new window)
Statistics cookies collect information anonymously. This information helps us understand how visitors use our website.
Google Analytics is a powerful tool that tracks and analyzes website traffic for informed marketing decisions.
Service URL: business.safety.google (opens in a new window)