Technical Paper | Southwestern Petroleum Short Course 2010
Sucker Rod Coupling Friction in HDPE-Lined Tubing

Sucker rod coupling friction affects rod loads in pumping wells and can cause repeated failures. This technical paper compares HDPE-lined and bare steel tubing to examine how temperature and side loading affect coupling drag.

Mike Berry, Mike Berry Consulting; Rob Davis, Western Falcon; John Patterson, ConocoPhillips.
Historical Context

Originally published in 2010. Field results, economic assumptions, product information, and standards references reflect the reporting period of the original paper.

Table of Contents

Abstract

Sucker rod coupling friction values are used by rod design software to calculate rod loads for bare steel tubing on steel couplings. The friction values for sucker rod couplings on HDPE-lined tubing are not yet known or defined. Therefore, rod load calculations in HDPE-lined tubing are problematic. Tests were performed to compare the coupling friction in HDPE-lined tubing compared to bare steel tubing at various temperatures and side loads. The objective was to find the drag ratio of rod couplings on HDPE-lined tubing to that of bare steel tubing at various temperatures. The data was used to develop an equation to calculate the drag in HDPE-lined tubing compared to that of bare steel tubing as a function of temperature. Although not quantitatively analyzed in this study, a side load capacity difference between HDPE-lined and bare tubing was also observed.

Background

It is common for many oil and gas operators to utilize software to predict loads and design complete rod strings in reciprocating beam pumped wells. These programs use a baseline value for the friction component of load experienced between the sucker rod couplings and the tubing ID. It is not the intent of this study to prove or dispute the absolute values used for the friction between bare steel tubing and rod couplings. Instead, it is desired to compare the measured friction of HDPE ID-lined tubing to bare steel tubing in similar conditions using the same type of sucker rod couplings.

It is hoped that a drag ratio between HDPE-lined and bare steel tubing can be quantitatively derived to help with problematic rod load calculations when using HDPE-lined tubulars. Ultimately, it is desirable to quantitate and predict the friction values of sucker rod couplings in HDPE-lined tubing.

It is believed that the material properties important to wear resistance do not change much as a function of temperature for steel under typical downhole production conditions. Current calculations do not indicate a temperature dependence of friction values between sucker rod couplings and the ID of bare tubing. However, the mechanical properties of HDPE can change significantly in downhole conditions (even below 200°F) and it is unknown if these changes will affect the friction properties of the plastic. For this reason, the HDPE-lined tubing was evaluated at various temperatures.

Test apparatus

The test fixture (Figure 1) was a previous design located at the Norris Rod facility in Tulsa, OK. ConocoPhillips modified the equipment to include instrumentation, a circulation pump and a heater. The test bench incorporated two polished rods that reciprocated tubing carriers and tubing samples across a series of rollers so two samples can be tested simultaneously in the fixture (Figure 2). The tubing carriers were immersed in water during the test. Sucker rod couplings were held against the tubing ID with various weights (ranging from 20 to 170 pounds of side load) to simulate different side loads as the tubing reciprocated back and forth in the carriers (Figure 4).

In order to contain the fluid in the test area, the polished rods pass through “stuffing boxes” on the end of the fluid chamber. Load cells were installed between the reciprocating drive mechanism and the end of the polished rods (Figure 3). The load cells are capable of operating in both compression and tension. Although this apparatus utilizes moving tubing and relatively stationary sucker rod couplings (opposite of typical well conditions), it duplicates the acceleration and deceleration of the reciprocating motion of rod strings in beam pumped wells.

Safety procedures dictated that only water could be used in the test chamber. It is believed that exposure to even small amounts of liquid hydrocarbons enhances the lubricity of the HDPE liners. As many rod pumped wells contain liquid hydrocarbons, the HDPE-lined samples were soaked in kerosene overnight prior to testing.

Test fixture and sample photographs

Figures 1 to 4 show the test fixture, installed tubing samples, load cells, and the fixture in operation.

Reciprocating friction test fixture at the Norris Rod facility in Tulsa, Oklahoma.

 

Figure 1 – Test Fixture
Two tubing samples and their carriers installed in the friction test fixture.

 

Figure 2 – Installed Test Samples
Load cells installed between the reciprocating drive and polished rods.

 

Figure 3 – Installed Load Cells
Test fixture operating with weights that apply side load to the coupling contact.

 

Figure 4 – Test Fixture in Operation

Test procedure

The test matrix was designed to evaluate several variables including side loads, temperature effects on the thermoplastic liner material, and the presence/absence of a HDPE liner in the tubing as they alter the friction of steel sucker rod boxes on the tubing ID.

The load cells were calibrated in compression prior to running any tests. In order to minimize any differences of geometry in the tubing ID versus the rod boxes, bare 2 3/8-inch (nominal ID of 1.995-inch) tubing samples and HDPE-lined 2 7/8-inch (nominal ID with liner of 2.16-inch) were compared and used in all tests. At every new temperature for the lined samples, a new tubing sample was used. Prior to collecting any data, a “break-in” run was allowed to establish a “nominal” wear surface on all samples. Also, new sucker rod boxes were used for every new sample.

The data was collected using a Monarch DC1250 data logger. Samples were taken at an interval of every 0.05 seconds. The test fixture operated at approximately 12 strokes per minute; therefore, approximately 102 data points were taken during every complete stroke.

Initially, a run was conducted without any sucker rod box load on the tubing samples in the carriage to determine the base load of the apparatus (primarily from the rollers under the tubing sample carriage and stuffing box). (Figures 5-8) Then the steel samples were run at room temperature to establish the baseline friction value of the sucker rods on bare steel tubing (Figures 9-12). The HDPE-lined samples were evaluated at various temperatures ranging from 87°F to 170°F (Figures 13-16).

Data filtering and analysis

The initial review of the data indicated a fair amount of noise in the data. It is believed that the noise was from several factors including the high sample rate, dynamic nature of the test and sensitivity of the load cells. In an effort to eliminate the obvious noise, hi/low filters were utilized and the data was smoothed with a three element running average. Finally to create a “composite” stroke pattern for each data set, twelve strokes worth of smoothed data were overlaid.

The data was not symmetrical in the “up stroke” (tension) and “down stroke” (compression) directions. It is believed that this was because the load cells were only calibrated in the compression direction and not calibrated in the tension direction. Also, one of the test channels (two samples were fitted in the apparatus simultaneously), Channel A, did not produce consistent results. For these reasons, the data analysis was all based on the “down stroke” (compression) data from Channel B.

Since the drag was measured outside of the stuffing box and inside the test carriage, the drag from both the stuffing box and the roller drag on the test carriage were subtracted from the data to get the actual drag of the sucker rod couplings on the tubing ID.

The supporting raw, filtered, and composite measurement plots are retained in Figures 5 to 16 below. The final comparison plots are Figures 17 to 21.

Test summary

Drag measurements were made at the “top” of the polished rod. These measurements are shown in Figure 17. Side load friction should be zero with a zero side load. However, there was a “stuffing box” between the load cells and the test samples. This friction is assumed to be a constant at a given temperature and can be subtracted out of the measurements by subtracting the zero side load friction from the measured values. This has been done in Figure 18. The values shown in Figure 18 are the coupling friction plus the roller friction. Note roller friction includes the fluid resistance of the tubing sample carriages moving in the fluid bath. If we subtract the roller friction from these values we are left with the coupling friction. This is shown in Figure 19.

Figures 17 to 19 show the polished rod drag, roller drag, and coupling drag relationships for the tested samples.

Channel B compression drag at the polished rod, including fixture friction, plotted against side load for steel, rollers, and lined tubing at several temperatures.

 

Figure 17 – Polished Rod Drag Relationships
Channel B drag after the zero side load correction, retaining the coupling and roller contributions.

 

Figure 18 – Roller Drag Relationships
Coupling drag after subtraction of fixture friction, compared across bare steel and lined tubing temperatures.

 

Figure 19 – Coupling Drag Data

The data yields a distinct pattern for the coupling drag with respect to the temperature differences in the lined tubing and a significant difference between the lined tubing and bare steel tubing with one exception. The first tested lined sample, evaluated at the lowest temperature of 87°F, does behave like all of the other temperature data. The reasons for this are fully understood. Because of this, the 87°F data was excluded from the final relationship so the range of validity of this relationship is limited to 97-170°F.

We can now divide the lined tubing coupling friction values by the corresponding bare steel tubing drag to obtain the drag ratio between bare and lined tubing at the various test temperatures. This is shown in Figure 20. The data set now shows a constant drag ratio at each tested temperature. These drag ratios range from 0.50 to 0.65 over the temperature range of 98°F to 170°F.

Figure 20 compares HDPE-to-steel drag ratios at the tested temperatures and side loads.

HDPE to steel coupling drag ratios against side load, including the excluded 87 degree Fahrenheit series; the steel reference is normalized to one.

 

Figure 20 – Poly/Steel Drag Ratio Data

These values can now be plotted as a function of temperature as shown in Figure 21. From this we derive a correlation for the drag ratio of HDPE-lined to bare steel tubing over the temperature range of 98°F to 170°F. The relationships are:

DRHDPE/Steel = 0.002 × T + 0.32

where T is the temperature in degrees F.

DHDPE = DSteel × DRHDPE/Steel

Figure 21 plots the HDPE-to-steel drag ratio against temperature.

HDPE to steel coupling drag ratio plotted against temperature for the retained data; the chart displays a fitted intercept of 0.3197.

 

Figure 21 – HDPE/Steel Drag Ratio Relationship

NOTE: A few reservations should be noted concerning this relationship. As previously mentioned, the data required filtering to eliminate noise. The data taken on the HDPE liner at 87°F did not fall in line with the data (measured load versus side load) from other temperatures which were all parallel. It was also discovered that the drag component produced by the stuffing box was temperature dependent. There is also some question if the drag component of the carriage/rollers and the steel are also temperature dependent.

Conclusions

It was observed that sucker rod coupling friction in HDPE-lined tubing is less than in bare steel tubing. The steel was significantly compromised by increasing side loads and the HDPE liner was much more resilient and handled the higher side loads better indicating that the HDPE liner has a higher side load capacity than bare steel tubing.

This initial data set yielded consistently linear results; however, additional roller friction testing is recommended to refine the HDPE/Steel drag ratio equation.

Supporting measurement figures

Roller and fixture friction

Figures 5 to 8 show raw, averaged, and composite roller-friction data, followed by the corresponding friction relationships.

Unfiltered roller drag measurements at 75 degrees Fahrenheit and 150 pounds side load, showing noisy values from both channels.

 

Figure 5 – Raw Roller Friction Data
The roller drag measurements after a three-element running average filter.

 

Figure 6 – Average Roller Friction Data
Composite roller drag stroke patterns and average compression and tension values.

 

Figure 7 – Composite Roller Friction Data
Fitted roller drag relationships against applied load for the two test channels.

 

Figure 8 – Roller Friction Relationships

Bare steel tubing reference measurements

Figures 9 to 12 show raw, averaged, and composite bare-tubing friction data, followed by the corresponding friction relationships.

Unfiltered bare steel tubing drag measurements with two couplings at 89 degrees Fahrenheit and 93 pounds side load.

 

Figure 9 – Raw Bare Tubing Friction Data
Running average filtered drag measurements for the bare steel tubing example.

 

Figure 10 – Average Bare Tubing Friction Data
Composite bare steel tubing stroke patterns and average drag values.

 

Figure 11 – Composite Bare Tubing Friction Data
Fitted bare steel tubing drag relationships against load, with a chart title showing 85 degrees Fahrenheit.

 

Figure 12 – Bare Tubing Friction Relationships

HDPE-lined tubing example measurements

Figures 13 to 16 show raw, averaged, and composite HDPE-lined tubing friction data, followed by the corresponding friction relationships.

Unfiltered measurements for a typical HDPE lined tubing example at 125 degrees Fahrenheit and zero pounds side load.

 

Figure 13 – Typical Raw Lined Tubing Friction Data
The HDPE lined tubing example after running average filtering.

 

Figure 14 – Typical Avg. Lined Tubing Friction Data
Composite stroke patterns and average drag for the HDPE lined tubing example.

 

Figure 15 – Typical Composite Lined Tbg. Friction Data
Fitted HDPE lined tubing drag relationships against load at 125 degrees Fahrenheit.

 

Figure 16 – Typical Lined Tubing Friction Relationships

Acknowledgements

The authors are greatly appreciative of the following contributors:

  • John Patterson and ConocoPhillips for providing the test concept and funding
  • Mike Berry for turning the test concept into a viable reality with usable data
  • Chris Rust and Norris Rods for providing the test fixture, rods and couplings
  • Rob Davis and Western Falcon for providing the bare and HDPE-lined tubing
  • Tom Ellis and Western Falcon for assisting with the testing

The authors would also like to graciously recognize their co-workers at Western Falcon Energy Services and our customers for their help and contributions in making this paper possible.

Discuss your downhole operating conditions

If your wells are experiencing recurring corrosion or rod-on-tubing wear failures, discuss the operating conditions and failure history with Western Falcon Energy Services. Share the available well data and planned treatment or intervention procedures to support a discussion of suitable materials and mitigation options.